your location:home page > Products > Functional & Effect Materials > Hollow Glass Microspheres

Hollow Glass Microspheres

Product Summary

Hollow Glass Microspheres are lightweight hollow spherical glass-based functional fillers designed for density reduction, lightweighting and formulation development.

Material Type: Hollow spherical glass-based filler powder

Functional Direction: density reduction, lightweighting, dimensional stability, shrinkage reduction and thermal insulation testing direction

Typical Systems: coatings, adhesives, sealants, plastics, rubber, resins and composite materials

Application Note: application guides are available for coatings, plastics & composites, adhesives, sealants, putty and general processing evaluation.

Testing Note: final suitability should be confirmed in the customer’s own formulation, dosage, substrate and processing conditions.

Hollow Glass Microspheres for Lightweight Functional Filler Applications

Hollow Glass Microspheres, also known as Hollow Glass Beads or Glass Bubbles, are lightweight hollow spherical glass-based functional fillers for density reduction, lightweighting and formulation development.

They can be evaluated in selected coatings, adhesives, sealants, plastics, rubber, resins and composite materials where lower density, dimensional stability, shrinkage reduction or insulation-related performance is required.

Final suitability should be confirmed through sample testing in the customer’s own formulation, dosage, substrate and processing conditions.

Technical Overview

Product NameHollow Glass Microspheres
Also Known AsHollow Glass Beads / Glass Bubbles
Material TypeHollow spherical glass-based functional filler powder
Functional DirectionDensity reduction, lightweighting, dimensional stability, shrinkage reduction and thermal insulation testing direction
Typical SystemsCoatings, adhesives, sealants, plastics, rubber, resins and composite materials

Typical Technical Data

General product-family typical data for initial evaluation only. Values are not final specifications and depend on the confirmed grade, batch, application system and agreed test method.

PropertyTypical / General InformationNotes
AppearanceWhite fine powderVisual reference
Particle morphologyHollow spherical glass-based particlesGrade-specific distribution
Chemical typeGlass-based inorganic microspheresExact composition depends on confirmed grade
True densityTypical reference range: 0.10–0.70 g/cm³Confirm selected grade
Bulk densityTypical reference range: 0.10–0.40 g/cm³Grade and packing dependent
Particle sizeTypical reference range: 10–200 μmD10 / D50 / D90 are grade-specific
Softening pointReference: ≥600°CNot a guaranteed processing temperature limit
Water solubilityNegligible / insoluble in normal useReference only

What Are Hollow Glass Microspheres?

Hollow Glass Microspheres are fine white powder materials with a hollow spherical particle structure. Compared with many solid mineral fillers or solid glass beads, their hollow internal structure provides a lower-density filler option for selected industrial formulations.

They are mainly used as functional fillers, not as reflective glass beads, decorative glass beads, pigments or photoluminescent materials.

How Hollow Glass Microspheres Work

Hollow Glass Microspheres have a hollow spherical structure. In selected formulations, this structure may help reduce finished density, support lightweight design and contribute to insulation-related testing.

Final performance depends on grade, dosage, matrix, processing shear, particle size, density, compressive strength and test method.

Key Functional Directions

Typical Applications

Coatings

Hollow Glass Microspheres can be evaluated in thermal insulation coatings, waterproof coatings, anti-corrosion coatings, roof and wall coatings and lightweight industrial coating systems.

Adhesives, Sealants and Putty

They can be tested as lightweight fillers in selected adhesive, sealant and putty systems. Typical evaluation directions include density reduction, shrinkage reduction, workability adjustment and lightweight gap-filling performance.

Plastics and Rubber

Hollow Glass Microspheres may be evaluated in selected plastic and rubber systems where density reduction or lightweighting is required. Grade selection should consider processing temperature, pressure, shear level and particle breakage behavior during extrusion, injection molding or compounding.

Resins and Composite Materials

They can be tested in epoxy, PU, polyester resin, SMC/BMC and other lightweight composite formulation systems.

Marine buoyancy, oilfield cementing, aerospace or other high-end project applications require project-specific testing, documents and approval.

Quick Grade Selection Guide

Customer TargetSuggested Direction
Lower final densityLower-density grade direction
Thin coating or smoother surfaceFiner particle size direction
Higher shear or pressureHigher compressive strength direction
Adhesive or sealant useWorkability and shrinkage-balance direction
Plastic processingBreakage-resistance direction
Resin or composite systemDensity and mechanical balance direction
Thermal insulation testingConfirm loading level, coating thickness and test method

Processing Notes

Documents

DocumentStatus
General TDSDownload TDS
Product BrochureAvailable upon request
Grade Selection SheetAvailable upon request for initial sample selection
Processing & Handling GuideAvailable upon request for processing and handling reference
Application GuidesAvailable upon request for coatings, plastics & composites, adhesives, sealants and putty applications
SDS / MSDSAvailable upon request based on confirmed grade and project requirements
COAAvailable by batch
Compliance DocumentsAvailability must be confirmed for the selected grade and required document scope

For a consolidated overview of public downloads and request-based product documents, visit the Document & Verification Center.

Before requesting a sample, review the Sample Testing Guide and prepare your application, binder / resin / polymer system, processing conditions, target density, strength requirements and testing plan.

Application Guides Available

NewColorChem provides application-oriented technical guides to support initial evaluation in different formulation systems.

These guides are provided for initial application evaluation only and do not replace grade-specific TDS, SDS, batch COA or customer-side formulation testing.

Sample Request Information

To recommend a suitable grade, please provide the following information:

FAQ

What are hollow glass microspheres?

Hollow glass microspheres are hollow spherical glass-based particles used as lightweight functional fillers in selected coating, plastic, adhesive, sealant, resin and composite systems.

Are hollow glass microspheres the same as reflective glass beads?

No. Reflective glass beads are mainly selected for optical reflection. Hollow glass microspheres are mainly selected for density reduction, lightweighting and insulation-related formulation development.

Can hollow glass microspheres be used in coatings?

They can be evaluated in selected coatings, including thermal insulation coatings, waterproof coatings, anti-corrosion coatings and lightweight coating systems. Actual performance depends on formulation and processing conditions.

Can they be used in plastics?

They can be tested in selected plastic and rubber systems. Grade selection should consider compressive strength, particle size, processing temperature, pressure and breakage behavior.

Do hollow glass microspheres improve thermal insulation?

They can be evaluated in thermal insulation-related systems. Final performance depends on grade, dosage, coating thickness, formulation design and test method.

Can they reduce product weight?

They may help reduce density in selected formulations, but the actual weight reduction should be confirmed by customer testing.

Are they suitable for high-shear processing?

High-shear processing requires careful grade selection and breakage testing. Higher strength grades may be needed depending on the process.

What documents are available?

General TDS is available for initial evaluation. Product Brochure, Grade Selection Sheet, Processing & Handling Guide, application guides and SDS can be provided upon request. COA is available by batch.

Can NewColorChem recommend a grade?

Yes. Please provide your application, resin or binder system, processing method, target density, required particle size, strength requirement and testing plan.

Contact NewColorChem

For samples, TDS, SDS or grade selection support, please contact:

Michael Yao
NewColorChem | Xiamen Magic Color Technology Co., Ltd.
Email: [email protected]
WhatsApp: +86 18906035051
Website: colorchangepigment.com

FEATURE PRODUCTS